Request a Quote · UNT-G-SFP
Home  /  XGS-PON / GPON  /  UNT-G-SFP GPON SFP ONT Stick
UNT-G-SFP GPON SFP ONT Stick
GPON ONT · SFP Stick

UNT-G-SFP GPON SFP ONT Stick

The UNT-G-SFP is a complete GPON ONU inside a standard SFP transceiver module — a GPON ONU stick (SFP ONT). It converts the host device's SFP interface into a GPON interface — no separate ONT box — and is compatible with devices equipped with an SFP interface, with full OMCI remote management from the OLT.

2.5G / 1.25G GPON line rate
SFP (MSA) · 1×GE host interface
Class B+ PX20+ optics
ITU-T G.984.x · OMCI
≤−28 dBm
Receiver sensitivity
20 km
PON transmission distance
≤4 W
Power consumption (DC 3.3 V)
35 g
Module weight
Key Features

The whole ONU, inside the module

The UNT-G-SFP integrates complete GPON ONU functionality into the SFP package — designed for GPON CPE integration and embedded ONU applications.

Complete GPON ONU in an SFP module

The full ONU — GPON MAC, optics and OMCI stack — lives inside a standard SFP transceiver. The host device gains a standards-based GPON network side through its existing SFP port, with no separate ONT enclosure, power supply or mounting.

Host-side advantages

Reusing the host's SFP port saves CPE space and power and shortens the bill of materials. The module is hot-swappable, so replacement in the field is a seconds-long swap — and the same host design serves fiber and copper variants by changing one module.

Ethernet service delivery in SFU mode

As an SFU (single-family-unit) bridging ONU it sits behind the host router and delivers Ethernet services cleanly: 802.1D and 802.1ad bridging, configurable VLAN awareness with transparent, tagging, translation and trunk modes, 802.1p class of service with priority queues, plus IGMPv2/v3 and PPPoE forwarding.

Designed for CPE integration

Built for equipment makers and OEM/ODM programs: a standard SFP MSA footprint, a fully documented 20-pin host interface (including Dying Gasp detection), DC 3.3 V power, and OMCI provisioning from the OLT — integrate it once, ship it in your own gateway, router or embedded host.

Interface

Two interfaces, one stick

One end speaks PON to the network; the other speaks Gigabit Ethernet to the host. Everything between is the ONT.

UNT-G-SFP GPON SFP ONT Stick, annotated
1
SC/UPC optical portClass B+ / PX20+ optics · the bail latch releases the stick from the host cage
2
Ribbed metal housingStandard SFP MSA metal package — the ribs shed heat at full line rate, no fan required
3
SFP edge connector (host end)Gold-finger 20-pin SFP electrical interface · 1×GE data plus module signals — full pin description in the specifications below
•
Product label (unnumbered)Model, serial number and CE marking on the housing · Dying Gasp detection is carried on pin 7 for host integration
Applications

Where the stick works

One module, three ways to ship GPON: inside your own CPE, behind an operator's router, or in any host that already has an SFP port.

OLT 1:N Your CPE + UNT-G-SFP inside

CPE & gateway integration (OEM)

Device makers build GPON straight into gateways and routers — the stick is the ONU, so the host board needs only a standard SFP cage and 3.3 V power.

OLT 1:N Router SFU bridging

Behind-router SFU deployments

Operators deploy the stick as an SFU bridge in the subscriber's router: services are separated by VLAN, the router keeps routing, the OLT keeps full OMCI control of the ONU.

OLT 1:N SFP Host switch · media converter

Any host with an SFP port

Switches, media converters and embedded systems with a free SFP port gain a GPON uplink without a hardware redesign — the module is compatible with devices equipped with an SFP interface.

Specifications

Technical specifications

Every value below is from the official UNT-G-SFP datasheet (UGRID-DS-UNT-G-SFP-R00). Contact us for interoperability test reports.

PON & optics
PON standardITU-T G.984.x GPON · CTC 3.0
Line rate2.488 Gbps downstream / 1.244 Gbps upstream
Optics classClass B+ / PX20+
Transmitting optical power0 to +4 dBm
Receiving sensitivity≤ −28 dBm
WavelengthTx 1310 nm · Rx 1490 nm
Optical connectorSC/UPC
Transmission distance20 km
Host interface & Ethernet
PackageStandard SFP module (MSA)
LAN interface1× GE Ethernet via the SFP connector
Device modeSFU (bridging mode)
Layer 2802.1D & 802.1ad bridging · configurable VLAN awareness (transparent / tagging / translation / trunk) · 802.1p CoS with priority queues
ForwardingIPv4 · PPPoE packet forwarding · IGMPv2/v3 packet forwarding
Management — OMCI
Management channelOMCI — full remote provisioning, monitoring and management from the OLT
Host pin description (SFP 20-pin)
Pin 1 — VeeTTransmitter ground (Note 1)
Pin 2 — Tx-FaultTransmitter fault indication · normal "0", fault: logic "1" output, LVTTL (Note 2)
Pin 3 — Tx-DisableTurns off the Tx laser (Note 3)
Pins 4 / 5 — Mod-Def(2) / Mod-Def(1)SDA I2C data line / SCL I2C clock line (Note 2)
Pin 6 — Mod-Def(0)Module absent, connected to VeeR (Note 2)
Pin 7 — Rate SelectFor Dying Gasp detection · input low active
Pin 8 — LOSLoss of signal (Note 2)
Pins 12 / 13 — RD− / RD+(Inv.) received data output
Pins 18 / 19 — TD+ / TD−(Inv.) transmit data in
Pins 9, 10, 11, 14, 17, 20 — VeeR / VeeTReceiver / transmitter ground (Note 1)
Pins 15 / 16 — VccR / VccTReceiver / transmitter power
Host design notesNote 1: module circuit ground is isolated from module chassis ground within the module. Note 2: pull up with 4.7K–10KΩ to 3.13–3.47 V on the host board. Note 3: the pin is pulled up to VccT with a 4.7K–10KΩ resistor in the module.
Power & environment
Power supplyDC 3.3 V
Power consumption≤4 W
Dimensions & weight14.1 × 79 × 13.6 mm (H × W × D) · 35 g
Operating environment0 °C to +50 °C · 10%–90% RH, non-condensing
Storage environment−30 °C to +60 °C · 10%–90% RH, non-condensing
Interoperability

Tested to interwork

The UNT-G-SFP is standards-based — ITU-T G.984.x with OMCI management — and delivers interoperability with major OLT brands. On the host side, it fits any device with a standard SFP port.

UGrid OLTs — verified

  • U5 GPON OLT ✓ Verified
  • U10 XGS-PON / GPON Combo OLT (GPON mode) ✓ Verified

Third-party OLTs & host devices

  • Major-brand G.984.x GPON OLTs ✓ Interwork by design
  • Routers & gateways with an SFP cage ✓ Drop-in fit
  • Switches & CPE with a free SFP port ✓ Drop-in fit

An ONU stick, not another box. The UNT-G-SFP turns the host's own SFP port into the GPON interface — no separate ONT enclosure, no extra power supply (it runs on the host's 3.3 V rail). To the host it presents a standard 1×GE Ethernet uplink in SFU bridging mode; to the OLT it speaks standard OMCI, so it provisions and manages like any operator ONT, in the footprint of a transceiver.

Running a different OLT or host? Send us the model — we run interoperability testing on request and share the test report. The full third-party compatibility list is published with each test report.
Downloads

Documentation & software

Everything engineers and procurement need — one click away.

UNT-G-SFP Datasheet (PDF)GPON SFP ONT Stick · official datasheet, UGRID-DS-UNT-G-SFP-R00
Download
Host Integration Guide (PDF)SFP cage and pin-integration notes for equipment makers
Coming soon
FirmwareDelivered over OMCI from the OLT · release notes
Coming soon
Interoperability Test ReportThird-party OLT test results
Coming soon
Ordering

Ordering information

UNT-G-SFP

  • Model — UNT-G-SFP · GPON, Class B+ / PX20+
  • Package — SFP · 1× GE host interface · compatible with host devices equipped with a standard SFP port
  • Connector — SC/UPC
Compare

GPON or XGS-PON stick?

Both sticks share the same idea — the ONT lives in the host's SFP cage. The choice is the PON generation.

UNT-G-SFP (GPON)UNT-XG-SFP (XGS-PON)
PON standardITU-T G.984.x GPONITU-T G.9807.1 XGS-PON
Line rate2.5 Gbps down / 1.25 Gbps up10 Gbps down / 10 Gbps up
OpticsClass B+ / PX20+ · Tx 0 to +4 dBm · Rx ≤ −28 dBmClass N1 · Tx +4 to +9 dBm · Rx −28.5 dBm
Wavelength1310 nm up / 1490 nm down1260–1280 nm up / 1575–1580 nm down
Optical connectorSC/UPCSC/APC or SC/UPC
Host interfaceSFP · 1× GESFP+ · XFI
Power≤4 W (DC 3.3 V)<2.1 W
Operating temperature0 °C to +50 °C−40 °C to +85 °C
Best forCost-effective GPON CPE and embedded ONU designs10G upgrades of existing gateways, switches, routers and backhaul
Related Products

Complete your access network

The UNT-G-SFP terminates on UGrid OLTs and pairs with the rest of the access portfolio.

U5
GPON OLT

U5 GPON OLT

View product →
U10
XGS-PON OLT

U10 XGS-PON / GPON Combo OLT

View product →
UNT XGS
XGS-PON ONT

UNT XGS-PON ONT

View product →
uFT
AI + OTDR

uFT Fiber Testing System

Request a quote →
FAQ

UNT-G-SFP questions, answered

What is a GPON ONU stick?

A GPON ONU stick — also called an SFP ONT — is a complete GPON ONU (optical network unit) built into a standard SFP transceiver module. Plugged into a router, switch or CPE with an SFP cage, it turns the host's SFP port into the GPON interface, so no separate ONT box is needed. The UNT-G-SFP is UGrid's GPON ONU stick.

Which devices can host the UNT-G-SFP?

Any device with a standard SFP port: routers and gateways, L2/L3 switches and CPE. The host powers the stick at DC 3.3 V, and it draws ≤4 W.

Which OLTs does the UNT-G-SFP work with?

It is verified with UGrid's U5 GPON OLT and the U10 combo OLT in GPON mode, and — as a standards-based ITU-T G.984.x ONU with OMCI management — interworks by design with major-brand GPON OLTs.

How is the UNT-G-SFP managed?

From the OLT over OMCI, like any operator ONU. It runs in SFU bridging mode with full VLAN handling, so the host device keeps its own routing and services.

Get a quote for the UNT-G-SFP

Tell us about your deployment — our team typically responds within 2 business days.

Request a Quote